TECPEL CO., LTD.

Propel Quality Measurement.

Home

Company

About us

Contact us

Service

Product

Anemometers

Anemometer AVM-702

Anemometer Temp AVM-712

HotWire Anemometer AVM714

Anemometer AVM-715

Light Meter

DLM 530 ,Digital Light me

DLM 531,Digital Light met

DLM 536,Light Meter

UVA-830,UVA Light Meter

Calibrators

Process Calibrator CL-325

TemperatureCalibrator 326

TemperatureCalibrator 327

SoundLevel Calibrator 336

Clamp Meter-Digital

Clamp meter AC 1000A 2600

Clamp meter AC 1500A 2608

Clamp meter AC/DC 2605

Clamp meter TRMS 2606

Clamp meter AC 300A 036

Clamp meter 300A DCM 037

DCM-040, AC Leakage Tester

DPM-035, 1000A Amp AC/DC Power Meter

DCM-032, 0~400A AC, Temp

DCM-033, 0~400A AC/DC

DCM-039, 200A AC/DC 0.01A

DCM-041, AC 1000A Power

Clamp Transmitter

CA-600,600A AC/DC adapter

CA-60, AC/DC Clamp Adpater, 60mA DC/AC

CA-1000D, 200A, 1000A AC/DC Transducer

Electric Testers

DIM-571, Insulation Tester, Digital

ERT-580, Earth Resistance Tester

PHS-863, Phase Sequence Indicator

LP-2811, Digital Loop Impdeance PSC Tester

SVD-588, High Volt. Detector

CT-581, Cable Tracer

DIM-570, Megohm, Insulation Meter

DIM-572,Insulation teste

High Voltage Detector HVP

EMF Tester Gauss Meter

EMF-701A,EMF Tester

EMF 701,EMF Field Tester

Function Generator

FG-15, 15MHz Signal FG

FG-52 , 5MHz Signal FG

SFG-2004,4MHz Sigal FG

SFG-2104,4MHz Sigal FG

SFG-2007,7MHz Sigal FG

SFG-2107,7MHz Sigal FG

SFG-2110,10MHz Sigal FG

SFG-2010,10MHz Sigal FG

FG-32, 3MHz Signal FG

SFG-2020,20MHz Sigal FG

SFG-2120,20MHz Sigal FG

LCR meter

LCR-200 Instrument

LCR-610, Zero Adjust

LCR-612, 1KHz/120Hz, Dual Display, Auto Ranging

LCR Bridge LCR -819

Manometer

Moisture Meter

Multimeters-Digital

DMM-8088, Automotive DMM

DMM-8060, 3 3/4 Digi Temp

DMM-8061, 3 3/4 Digit, RS-232

DMM-8007, Cap, Induct

DMM-8050,Multimeters

DMM-120,Low Cost Meter

DMM-123,Low Cost Meter

DMM 124,Low Cost Meter

DMM-125, Low cost, 3200 Counts

DMM-134, Palm Size, Temp.

DMM-135, Palm size, Autorange

DMM-113B, Pocket type

AMM-110, Analog Multimeter

DMM-129A, RS-232, 3 3/4 D

DMM-168,Multimeter

DMM --8020,Multimeter

UT-58A Multimeter

UT-58C Multimeter

UT-803,Digital Multimeter

UT-30B Low Cost Meter

UT-10A,Pocket Multimeter

UT-70A Multimeter

UT-71A,Multimeter

UT-70B Multimeter

UT-71D Multimeter

UT-71E Multimeter

GDM-8135 Multimeter

GDM-8034 Multimeter

GDM-8145,Multimeter

GDM 8245,Multimeter

PH Meter-Digital

SM-850,Salinity Meter

pH meter pH-870 RS-232

pH meter pH-703

pH meter pH-705

pH meter pH-706

pH meter pH-707

pH meter pH-709

pH meter pH-871

pH meter pH-873

PE-148,pH Electrode

PE-148N, Electrode

ORP-148G

PE-149G,pH Electrode

PE-149G

DO-1610,Disolved Oxygen M

DO-1609, Oxygen Meter

Power Supply-DC

TPS-3020, 0-30V, 0-2A

TPT-3025, +/- 30V/ 2.5A

PPS-3520, 0~35V, 0~ 2A x 2

GPC-3030DQ ,30V/ 3A

GPC-3030D, 30V/ 3A

GPS-2303,0~30V/0-3A

GPS-3303,0~30V, 0~3A

GPS-4251,0~25V ,0~0.5A

GPS-4303 ,0~30V, 0~3A

GPS-3030D,0 ~ 30V,0 ~ 3 A

GPS-3030DD,0 ~ 30V,0 ~ 3A

Sound Level Meters

DSL-331, Sound Level Datalogger

DSL-330, Sound Level Meter

DSL-332, Sound Level Meter

DSL-336, Sound Calibrator

Tachometer-Digital

RM1500,Tachometer

RM 1501,Tachometer

RM1502,Tachometer

DT-2236A Contact Tachomet

DT-2239A Contact Tachomet

Thickness Gauge-Coating

Temperature meter

DTM-800,Thermometers

CL 327,Temperature Meter

CL326,Thermometer

DTM-305B, Single Input

DTM-305, Single Input

DTM-305C Temperature Mete

DTM-307B, Dual Input

DTM-316, Dual Input, RS-232

DTM-307, Dual Input

DTM-506B, K/J/T/E/R/S/N-Types

DTM-507,Thermometer

DTM-3101, Thermometer

DTM-3102 Thermometer

DTM-3103,Thermometer

DTM-322, Data logger

DTM-315, Single Input, RS-232

DIT513 Thermometer

DIT-515,Thermometer

DIT-510,Thermometer

DIT-512,Thermometers

DIT-501A,Thermometer

DTM-323,Thermometer

Temperature Datalogger

DTM-317, Single Input Datalogger

DTM-318, Dual Input Datalogger

DTM-319, 4-input recorder

TR-51S Thermo Recorder

TR-52S Thermo Recorder

TR-71U Thermo Recorders

TR-72U Thermo Recorder

TR-73U Thermo Recorder

TP-125, Thermo Recorder

TR-71W,Web ThermoRecorde

TR-72W,Web Thermo Recorde

DTM-322,Thermometer

Temp-Humidity meters

DTM-321 RS-232 Hygrometer

DTM-550,Hygrometer

DTM-551,Thermometer

DTM-304,Thermometer

DTM-303,Thermometer

DTM-300,Thermometer

DTM-301,Thermometer

TRH-301,Humidity Transmit

TRH- 302,Humidity Transmi

TRH-303,Humidity Transmit

Oscilloscope Probes

LF-190E, Probes

LF-210E Probes

LF-250 ,Probes

AL-01 & TL-01 Test Leads

AL-03,Test Leads

TL-02,Test Leads

TL-03 ,Test Leads

LS-08 ,Test Lead Set

LS-12 Test Lead Set

Oscilloscope

GOS-620,Oscilloscope

GDS-2204,Oscilloscope

GDS-2202 ,Oscilloscope

GDS-2104 ,Oscilloscope

GDS-2102 Oscilloscope

GDS-2064 Oscilloscope

GDS-2062 Oscilloscope

GOS-6103C,Oscilloscope

GOS-6112,Oscilloscope

GOS-6103,Oscilloscope

GOS-653G,Oscilloscope

GDS-1022,Oscilloscope

GDS-1042,Oscilloscope

GDS- 1102,Oscilloscope

Voltage Test Probe, Meter

HV-40,High Meter

HVP-40M,High Voltage Prob

HVP-275,Detector

HVP-15HF,Probe

Differential Probes

HP-25, DifferentialProbe

HP-100,Differential Probe

DP-25,Differential Probe

TPK-04,Surface Probes

Thermocouple Temperature

TPK-07,Magnetized Probes

TPK-02B,Thermocouples

TPK-02A,Thermocouples

TPK-06 ,Magnetized Probes

TPK-01M,Thermocouple

TPK-01F,Thermocouple

TPK-04L,Thermocouple

TPK-04LS,Thermocouples

TPK-03S,Immersion Probes

TPK-03,Probes

PT100-01,Sensor

TPK-05,Air Probe

TPK-03XP,Thermocouple

TPK-03SM,Thermocouple

TPK-01FM-10M,Thermocouple

K type Thermocouple

TPK-04S,Surface Probe

TPK-01,Bead Probe

Chinese

High Voltage Proximity Detector ( HVP-275)


HVP-275
HVP-275
HVP-275 Features

‧ Sealed by " O" Ring.
‧ 8 voltage settings: 240Vac, 2kV, 6kV, 11kV, 22kV, 33kV,
132kV, and 275kV
‧ High bright LEDs visual indication
‧ Sound indication
‧ Easy-to-proov method
‧ Self-test selection
‧ Use 3 x 1.5V “C” batteries
‧ High impact nylon casing
‧ Non-contact work by proximity
‧ Compatible with most link sticks
‧ Light weight, robust, & compact
‧ Suitable for indoor and outdoor use
‧ Detect low voltage on any systems
‧ Easy access to batteries
‧ No special parts needed
‧ Three-year warranty
‧ Simple and efficient to use




  • Introduction:
    • The TECPEL HVP-275 is a high voltage proximity detector.
    • It has eight voltage detection settings from 240Vac to
    • 275kVac. The HVP-275 consists of an internal pickup
    • sensor plate, a sensitivity selector, a visual and a
    • sound annunciator. With the HVP-275, physical contact
    • with electrical conductors is not necessary when
    • testing for live lines. This tester works by proximity.
    • Its sensor senses the radiated field which surrounds
    • live conductors. Radiated field strength increases
    • with voltage and decreases quickly with distance or
    • earth shielding. The radiated field from a cable of
    • closely bunched conductors supplied by three phase
    • power tends to cancel (See “Limitations of use”
    • paragraph). Detecting distance of a 250Vac single
    • live wire is approximately 10cm. With a bunched
    • neutral and earth cable, as in a flexible cable, the
    • distance is reduced to 5cm.
    • Some of the typical uses are : identify and check live
    • cables; find fault in flexible cables; check earth
    • equipment; service neon lightning; trace live wires;
    • check high frequency radiation; detect residual or
    • induced voltages. For example, faults in damaged
    • flexible cables are found by applying low voltage to
    • each conductor. Earthing the remainder and moving
    • the tester along the cable until the change in condition
    • is obtained. (Flexible cables which are used in mining
    • and building industries, are readily repairable when
    • the break in the cable is located.)
    • When testing for high voltage, the rotary switch
    • (attenuator) is used to identify and differentiate
    • various HV live cables. The tester must be used in
    • conjunction with a long and insulating rod when
    • measuring high voltage (kV). However, the HVP-275 is
    • a non-contact tester and it is advised that the tester
    • should never come into contact with cables (kV) as
    • this tester is merely a non-contact AC proximity tester.
    • Checking or proofing the tester is easy. Switch the
    • sensitivity to 240V and place the dome against a low
    • voltage live conductor or rub the dome with a cloth or
    • against an item of clothing as this generates a static
    • DC which triggers the detection of circuit. The light
    • and beeper should go “on” as if a live wire is being approached. Approaching the dome near a computer screen or a TV screen should also trigger
    • the tester while on the 240V selection. The power consumption of the 275HP is very low, and the
    • tester should always be tested as described above before using it.
  • Specifications:
    • Expected test results ( laboratory testing ) :
    • Range
    • 240V
    • 2kV
    • 6kV
    • 11kV
    • 22kV
    • 33kV
    • 132kV
    • 275kV
    • Typical observation of test results made in the field :
    • Range
    • 11kV
    • 22kV
    • 33kV
    • 132kV
    • 275kV
    • Operated from
    • Variable from 80V
    • or depending on the type of source
    • 250V
    • 500V
    • 1000V
    • 1500V
    • 4000V
    • 8000V
    • 22kV
    • Min. Detection MDV as % of
    • Voltage (MDV) Line Voltage
    • 1kV 9.1%
    • 2kV 9.1%
    • 3.1kV 9.4%
    • 12.5kV 9.5%
    • 22.5kV 8.2%
  • Limitation of usage.
    • Limitations of use :
    • It is recommended that the 275HP is not used in HV yards of mixed voltages.
    • In the presence of mixed voltages, the tester can become unreliable.
    • Problems can arise when the tertiary circuit of a 275/133/11kV transformer is
    • tested. The electric field of the HV and MV bus bars can trigger the detector when
    • it is about 3m above the ground. This is common with most of the electric field
    • voltage detectors, and the users should be aware of it. The tester can pick up
    • adjacent circuit to the one being tested and indicate the wrong information to the
    • user. Limitations of use :
    • It is recommended that the 275HP is not used in HV yards of mixed voltages.
    • In the presence of mixed voltages, the tester can become unreliable.
    • Problems can arise when the tertiary circuit of a 275/133/11kV transformer is
    • tested. The electric field of the HV and MV bus bars can trigger the detector when
    • it is about 3m above the ground. This is common with most of the electric field
    • voltage detectors, and the users should be aware of it. The tester can pick up
    • adjacent circuit to the one being tested and indicate the wrong information to the
    • user.





More TECPEL Test and Measurement
 
http://www.tecpel.com   http://www.tecpel.net        http://www.oka.com.tw/        http://www.tecpel.com.tw
E-mails:  
sales@tecpel.com   tecpel@seed.net.tw  oka@oka.com.tw
Copy Right (C) 1990~2011 Tecpel Co., Ltd. Taipei, Taiwan All Rights Reserved