Features: CE-Mark approval 3 1/2 digital 2000 counts with high resolution Display back-light feature K/J/T/E-types thermocouple selection dual input, HOLD function Highly accurate with 0.1% Auto range 0.1 ° /1 ° ° C/ ° F user-selective Auto power off function
Specifications:
Specifications:
Display: 3 1/2 digit liquid crystal display (LCD) with a maximum reading of 1999.
Over range: (OL) or (-OL) is displayed.
Zero: Automatic.
Low battery indication: The "Battery symbol" is displayed when the battery voltage drops below the operating level.
Measurement rate: 1 times/second.
Operating environment: 0 °C to 50 ° C, <70% R.H..
Storage environment: -20 °C to 60 ° C, 0 to 80% R.H. with battery removed from meter.
Accuracy: Stated accuracy at 23 ° C +/-5 ° C, <75% R.H..
Accuracy specification does not include type K thermocouple probe accuracy.
Dimensions: 195mm(H) x 92mm(W) x 53mm(D).
Weight: Approx. 250g. (including battery)
Temperature:
Temperature:
Measurement / Calibration Range
K-type (0.1 °C) -200 ° C to 1372 °C, -328 ° F to 1999 ° F
J-type (0.1 °C) -210 ° C to 1200 °C, -346 ° F to 1999 ° F
T-type (0.1 ° C) -200 ° C to 400 °C, -328 ° F to 752 °F
E-type (0.1 °C) -220 °C to 1000 °C, -364 °F to 1832 °F
According to temperature standard ITS-90
Accuracy: +/-(0.1%rdg + 1 ° C) on -60 °C to 1372 °C