TECPEL CO., LTD.

Propel Quality Measurement.

Home

Company

About us

Contact us

Service

Product

Anemometers

Anemometer AVM-702

Anemometer Temp AVM-712

HotWire Anemometer AVM714

Anemometer AVM-715

Light Meter

DLM 530 ,Digital Light me

DLM 531,Digital Light met

DLM 536,Light Meter

UVA-830,UVA Light Meter

Calibrators

Process Calibrator CL-325

TemperatureCalibrator 326

TemperatureCalibrator 327

SoundLevel Calibrator 336

Clamp Meter-Digital

Clamp meter AC 1000A 2600

Clamp meter AC 1500A 2608

Clamp meter AC/DC 2605

Clamp meter TRMS 2606

Clamp meter AC 300A 036

Clamp meter 300A DCM 037

DCM-040, AC Leakage Tester

DPM-035, 1000A Amp AC/DC Power Meter

DCM-032, 0~400A AC, Temp

DCM-033, 0~400A AC/DC

DCM-039, 200A AC/DC 0.01A

DCM-041, AC 1000A Power

Clamp Transmitter

CA-600,600A AC/DC adapter

CA-60, AC/DC Clamp Adpater, 60mA DC/AC

CA-1000D, 200A, 1000A AC/DC Transducer

Electric Testers

DIM-571, Insulation Tester, Digital

ERT-580, Earth Resistance Tester

PHS-863, Phase Sequence Indicator

LP-2811, Digital Loop Impdeance PSC Tester

SVD-588, High Volt. Detector

CT-581, Cable Tracer

DIM-570, Megohm, Insulation Meter

DIM-572,Insulation teste

High Voltage Detector HVP

EMF Tester Gauss Meter

EMF-701A,EMF Tester

EMF 701,EMF Field Tester

Function Generator

FG-15, 15MHz Signal FG

FG-52 , 5MHz Signal FG

SFG-2004,4MHz Sigal FG

SFG-2104,4MHz Sigal FG

SFG-2007,7MHz Sigal FG

SFG-2107,7MHz Sigal FG

SFG-2110,10MHz Sigal FG

SFG-2010,10MHz Sigal FG

FG-32, 3MHz Signal FG

SFG-2020,20MHz Sigal FG

SFG-2120,20MHz Sigal FG

LCR meter

LCR-200 Instrument

LCR-610, Zero Adjust

LCR-612, 1KHz/120Hz, Dual Display, Auto Ranging

LCR Bridge LCR -819

Manometer

Moisture Meter

Multimeters-Digital

DMM-8088, Automotive DMM

DMM-8060, 3 3/4 Digi Temp

DMM-8061, 3 3/4 Digit, RS-232

DMM-8007, Cap, Induct

DMM-8050,Multimeters

DMM-120,Low Cost Meter

DMM-123,Low Cost Meter

DMM 124,Low Cost Meter

DMM-125, Low cost, 3200 Counts

DMM-134, Palm Size, Temp.

DMM-135, Palm size, Autorange

DMM-113B, Pocket type

AMM-110, Analog Multimeter

DMM-129A, RS-232, 3 3/4 D

DMM-168,Multimeter

DMM --8020,Multimeter

UT-58A Multimeter

UT-58C Multimeter

UT-803,Digital Multimeter

UT-30B Low Cost Meter

UT-10A,Pocket Multimeter

UT-70A Multimeter

UT-71A,Multimeter

UT-70B Multimeter

UT-71D Multimeter

UT-71E Multimeter

GDM-8135 Multimeter

GDM-8034 Multimeter

GDM-8145,Multimeter

GDM 8245,Multimeter

PH Meter-Digital

SM-850,Salinity Meter

pH meter pH-870 RS-232

pH meter pH-703

pH meter pH-705

pH meter pH-706

pH meter pH-707

pH meter pH-709

pH meter pH-871

pH meter pH-873

PE-148,pH Electrode

PE-148N, Electrode

ORP-148G

PE-149G,pH Electrode

PE-149G

DO-1610,Disolved Oxygen M

DO-1609, Oxygen Meter

Power Supply-DC

TPS-3020, 0-30V, 0-2A

TPT-3025, +/- 30V/ 2.5A

PPS-3520, 0~35V, 0~ 2A x 2

GPC-3030DQ ,30V/ 3A

GPC-3030D, 30V/ 3A

GPS-2303,0~30V/0-3A

GPS-3303,0~30V, 0~3A

GPS-4251,0~25V ,0~0.5A

GPS-4303 ,0~30V, 0~3A

GPS-3030D,0 ~ 30V,0 ~ 3 A

GPS-3030DD,0 ~ 30V,0 ~ 3A

Sound Level Meters

DSL-331, Sound Level Datalogger

DSL-330, Sound Level Meter

DSL-332, Sound Level Meter

DSL-336, Sound Calibrator

Tachometer-Digital

RM1500,Tachometer

RM 1501,Tachometer

RM1502,Tachometer

DT-2236A Contact Tachomet

DT-2239A Contact Tachomet

Thickness Gauge-Coating

Temperature meter

DTM-800,Thermometers

CL 327,Temperature Meter

CL326,Thermometer

DTM-305B, Single Input

DTM-305, Single Input

DTM-305C Temperature Mete

DTM-307B, Dual Input

DTM-316, Dual Input, RS-232

DTM-307, Dual Input

DTM-506B, K/J/T/E/R/S/N-Types

DTM-507,Thermometer

DTM-3101, Thermometer

DTM-3102 Thermometer

DTM-3103,Thermometer

DTM-322, Data logger

DTM-315, Single Input, RS-232

DIT513 Thermometer

DIT-515,Thermometer

DIT-510,Thermometer

DIT-512,Thermometers

DIT-501A,Thermometer

DTM-323,Thermometer

Temperature Datalogger

DTM-317, Single Input Datalogger

DTM-318, Dual Input Datalogger

DTM-319, 4-input recorder

TR-51S Thermo Recorder

TR-52S Thermo Recorder

TR-71U Thermo Recorders

TR-72U Thermo Recorder

TR-73U Thermo Recorder

TP-125, Thermo Recorder

TR-71W,Web ThermoRecorde

TR-72W,Web Thermo Recorde

DTM-322,Thermometer

Temp-Humidity meters

DTM-321 RS-232 Hygrometer

DTM-550,Hygrometer

DTM-551,Thermometer

DTM-304,Thermometer

DTM-303,Thermometer

DTM-300,Thermometer

DTM-301,Thermometer

TRH-301,Humidity Transmit

TRH- 302,Humidity Transmi

TRH-303,Humidity Transmit

Oscilloscope Probes

LF-190E, Probes

LF-210E Probes

LF-250 ,Probes

AL-01 & TL-01 Test Leads

AL-03,Test Leads

TL-02,Test Leads

TL-03 ,Test Leads

LS-08 ,Test Lead Set

LS-12 Test Lead Set

Oscilloscope

GOS-620,Oscilloscope

GDS-2204,Oscilloscope

GDS-2202 ,Oscilloscope

GDS-2104 ,Oscilloscope

GDS-2102 Oscilloscope

GDS-2064 Oscilloscope

GDS-2062 Oscilloscope

GOS-6103C,Oscilloscope

GOS-6112,Oscilloscope

GOS-6103,Oscilloscope

GOS-653G,Oscilloscope

GDS-1022,Oscilloscope

GDS-1042,Oscilloscope

GDS- 1102,Oscilloscope

Voltage Test Probe, Meter

HV-40,High Meter

HVP-40M,High Voltage Prob

HVP-275,Detector

HVP-15HF,Probe

Differential Probes

HP-25, DifferentialProbe

HP-100,Differential Probe

DP-25,Differential Probe

TPK-04,Surface Probes

Thermocouple Temperature

TPK-07,Magnetized Probes

TPK-02B,Thermocouples

TPK-02A,Thermocouples

TPK-06 ,Magnetized Probes

TPK-01M,Thermocouple

TPK-01F,Thermocouple

TPK-04L,Thermocouple

TPK-04LS,Thermocouples

TPK-03S,Immersion Probes

TPK-03,Probes

PT100-01,Sensor

TPK-05,Air Probe

TPK-03XP,Thermocouple

TPK-03SM,Thermocouple

TPK-01FM-10M,Thermocouple

K type Thermocouple

TPK-04S,Surface Probe

TPK-01,Bead Probe

Chinese

100 MHz OSCILLOSCOPES ( GOS-6112)
GOS-6103,Oscilloscope
GOS-6103,Oscilloscope
  • GOS-6112/6103/6103C FEATURES
    • Cursor Readout Analog Oscilloscope
    • 100 MHz, Dual Channel, Delayed Sweep
    • Built-in 6 Digit Universal Counter (GOS-6103C)
    • 10 Sets Memory for Front Panel Setting Save & Recall (GOS-6103/GOS-6103C)
    • Time Base Auto-range (GOS-6103/GOS-6103C)
    • Cursor Readout with 7 Measurements
    • Panel Setup Lock of Digital-Control Functions
    • Buzzer Alarm
    • LED Indicators
    • TV Synchronization
    • Trigger Signal Output
    • Z-Axis Modulation Input
    • SMD Technology, High Stability and Reliability
    • ( GOS-6103C Without CE Approved.)

    • CRT
    • Type 6-inch rectangular type with internal graticule;
    • 0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)
    • Phosphor P31
    • Accelerating Potential 16 kV approx.(GOS-6103/GOS-6103C), 12kV approx.(GOS-6112)
    • Illumination Continuously adjustable (GOS-6103/GOS-6103C)
    • Z-axis input Coupling : DC
    • Sensitivity : 5V or more
    • Maximum input voltage : 30V(DC+AC peak) at 1kHz or less
    • Bandwidth : DC ~ 5MHz
    • --------------------------------------------------------------------------------
    • VERTICAL SYSTEM
    • Sensitivity 2mV ~ 5V / DIV,11 step in 1-2-5 sequence
    • Sensitivity Accuracy < 3% (5 DIV at the center of display)
    • Vernier Vertical Sensitivity Continuously variable to 1 / 2.5 or less panel-indicate value
    • Bandwidth(-3dB) DC ~ 100MHz (2mV/DIV : DC ~ 20MHz)
    • Rise Time 3.5nS (2mV/DIV : 17.5 nS)
    • Signal Delay Leading edge can be monitored
    • Max. Input Voltage 400V (DC+AC peak) at 1kHz or less
    • Input Coupling AC, DC, GND
    • Input Impedance 1MΩ+2%// approx. 25pF
    • Vertical Mode CH1, CH2, DUAL (CHOP/ALT), ADD, CH2 INV.
    • Bandwidth Limited 20MHz
    • Common-Mode Rejection Ratio 50 :1 or better at 50kHz
    • Dynamic Range 8 div at 60MHz;5 div at 100MHz (GOS-6112)
    • 8 div at 100MHz (GOS-6103/GOS-6103C)
    • --------------------------------------------------------------------------------
    • HORIZONTAL SYSTEM
    • Horizontal Modes MAIN (A), ALT, DELAY (B)
    • A(main)Sweep Time 50nS ~ 0.5S / DIV, continuously variable (UNCAL)
    • B(delay)Sweep Time 50nS ~ 50mS / DIV
    • Accuracy + 3% (+ 5% at x 10 MAG)
    • Sweep Magnification x 10 (maximum sweep time 5nS / DIV)
    • Hold Off Time Variable
    • Delay Time 1µS ~ 5S
    • Delay Jitter Better than 1:20000
    • Alternate Separation Variable
    • --------------------------------------------------------------------------------
    • TRIGGER
    • Trigger Modes AUTO, NORM, TV
    • Trigger Source CH1, CH2, LINE, EXT
    • Trigger Coupling AC, DC, HFR, LFR
    • Trigger Slope "+" or "-" polarity or TV sync polarity
    • Trigger Sensitivity Mode
    • Frequency
    • INT
    • EXT
    • AUTO
    • 10Hz~20MHz
    • 0.35 DIV 50 mV
    • 20MHz~100MHz
    • 1.5 DIV 150 mV
    • NORM
    • DC~20MHz
    • 0.35 DIV
    • 50 mV
    • 20MHz~100MHz
    • 1.5 DIV
    • 150 mV
    • TV
    • sync signal
    • 1 DIV
    • 200 mVpp
    • TV Sync TV-V, TV-H
    • Max. External Input Voltage 400V (DC+AC peak) at 1kHz
    • External Input Impedance 1MΩ + 5%, // approx. 25pF
    • --------------------------------------------------------------------------------
    • X-Y OPERATION
    • Mode X-axis :selectable CH1, CH2, EXT
    • Y-axis :selectable CH1, CH2, CH1 and CH2
    • Sensitivity Accuracy 2mV ~ 5V/DIV+3%; EXT : 0.1V/DIV+ 5%
    • X-axis Bandwidth DC ~ 500kHz (-3dB)
    • Phase Error 3º or less from DC ~ 50kHz
    • --------------------------------------------------------------------------------
    • OUTPUT SIGNAL
    • Trigger Signal Output Voltage : approx. 25mV/DIV into 50Ω
    • Frequency response : DC ~ 10MHz
    • Calibrator Output 1kHz Squarewave, 2Vpp+2%
    • --------------------------------------------------------------------------------
    • CURSOR READOUT FUNCTION
    • Cursor Measurement Function ΔV,ΔV%,ΔVdB,ΔT,1/ΔT,ΔT%,Δθ
    • Cursor Resolution 1 / 100 DIV
    • Effective Cursor Range Vertical : + 3DIV ; Horizontal : + 4DIV
    • Panel Setting Display Vertical : V/DIV(CH1,CH2), UNCAL, ALT/CHOP/ADD, INV, probe factor, AC/DC/GND
    • Horizontal : S / DIV(MTB,DTB), UNCAL, x 10MAG, delay time, HO
    • Trigger : source, coupling, slope, level, TV-V, TV-H
    • Others : X-Y, lock, save/recall MEM 0-9(GOS-6103/GOS-6103C)
    • --------------------------------------------------------------------------------
    • AUTO MEASUREMENT FUNCTION (GOS-6103C)
    • Parameter Function FREQ, PERIOD, +WIDTH, +DUTY ( + or - polarity selected by trigger slope)
    • Display Digits Max. 6-digits, decimal
    • Frequency Range 50Hz ~ 100MHz
    • Accuracy 1kHz ~ 100MHz : +0.01%;50Hz ~ 1kHz : +0.05%
    • Measuring Sensitivity >2 div (Measuring source selected from CH1 and CH2 as synchronous signal sources)
    • --------------------------------------------------------------------------------
    • SPECIAL FUNCTION
    • TIME/DIV Auto Range Provided (GOS-6103/GOS-6103C)
    • Panel Setting Save & Recall 10 sets (GOS-6103/GOS-6103C)
    • Panel Setups Lock Provided
    • --------------------------------------------------------------------------------
    • POWER SOURCE AC 100V / 120V / 230V + 10%, 50 / 60Hz
    • --------------------------------------------------------------------------------
    • ACCESSORIES Power cord x1,
    • Instruction manual x1,
    • Probes(10:1/1:1)x2
    • --------------------------------------------------------------------------------
    • DIMENSIONS & WEIGHT 310(W) x 150(H) x 455(D) mm;Approx. 9kg C





    More TECPEL Test and Measurement
     
    http://www.tecpel.com   http://www.tecpel.net        http://www.oka.com.tw/        http://www.tecpel.com.tw
    E-mails:  
    sales@tecpel.com   tecpel@seed.net.tw  oka@oka.com.tw
    Copy Right (C) 1990~2011 Tecpel Co., Ltd. Taipei, Taiwan All Rights Reserved